When biological samples enter ultra-low-temperature or liquid-nitrogen storage, the label becomes part of the sample's traceability system. Conventional labels may become brittle, lose adhesion or become unreadable after prolonged exposure to extreme cold and repeated freeze-thaw cycles, and once identification is lost the connection between the sample and its data may be difficult — or impossible — to recover. E-4812 is designed specifically for frozen laboratory sample identification, including polypropylene cryovials, test tubes and storage boxes. Once correctly applied, the label is designed to remain securely attached and clearly identifiable throughout long-term cryogenic storage, including temperatures down to −196°C.

| Parameter | Details |
|---|---|
| Facestock | |
| Material | White, flexible, coated biaxially oriented film from a co-extruded polymer blend |
| Basis weight | 55 g/m² (ISO 536) |
| Thickness | 56 µm (ISO 534) |
| Opacity | 85% (ISO 2471) |
| Printing | Flexographic, screen, offset, UV inkjet and thermal transfer |
| Adhesive | |
| Type | Permanent |
| Chemistry | Water-based acrylic |
| Initial tack | 7 N (FTM 9) |
| Application temperature | −80 °C — direct application to frozen surfaces; never apply while the container is immersed in liquid nitrogen |
| Service temperature | −196°C ~ +80°C |
| Release liner | |
| Material | White glassine liner |
| Basis weight | 62 g/m² (ISO 536) |
| Thickness | 54 µm (ISO 534) |
| Tensile strength (MD) | 7 kN/m (ISO 1924) |
| Tensile strength (CD) | 2.7 kN/m (ISO 1924) |
| Transparency | 48% (DIN 53147) |
| Product specification | |
| ETIA code | E-4812 |
| EAN | 6415788196878 |
| Total thickness | 132 µm |
| Freeze-thaw performance | Up to 10 cycles |
| Long-term storage | −150°C to −196°C, including liquid-nitrogen storage |
| Shelf life | 24 months from manufacture, stored at +20°C to +25°C and 40–50% RH (FINAT) |
No online download — samples and the TDS are sent one-to-one by email.